BeiJing Cape Golden Gas System Company LTD yelling@golden-cape.com
CI-PC56 Microprocessor Hydrogen Gas Analyzer Thermal Conductivity Type

CI-PC56 Microprocessor Hydrogen Gas Analyzer Thermal Conductivity Type

  • High Light

    microprocessor hydrogen gas analyzer

    ,

    thermal conductivity type hydrogen gas analyzer

    ,

    thermal conductivity type h2s analyzer

  • Sample Gas Flow
    150~300ml/mim
  • Accuracy
    ±2% F.S
  • Ambient Temp
    -10℃~+50℃
  • Stability
    <±1%.FS (168h)
  • Ambient Humidity
    <80%RH
  • Signal Output
    4~20mA
  • Measure Range
    10ppm~21%, 100ppm~21%, 1000ppm~21% O2
  • Range
    10.00~96.00% O2·
  • Place of Origin
    BeiJing
  • Brand Name
    cape golden
  • Certification
    CE ISO
  • Model Number
    CI-PC56
  • Minimum Order Quantity
    1
  • Delivery Time
    15 day
  • Payment Terms
    L/C, D/A, D/P, T/T, Western Union, MoneyGram

CI-PC56 Microprocessor Hydrogen Gas Analyzer Thermal Conductivity Type

CI-PC56 Thermal Conductivity Type Hydrogen Analyzer

 

CI-PC56 thermal conductivity gas analyzer is based on microprocessor and adopts heat-conduction sensor as the measuring unit. It has characteristics as high accuracy, good stability, complete functions, and long service life and so on. It applies to the accurate measurement of H2, Ar content in binary mixed gas.

 

Range

 

Component gas Background gas Min Range Max Range

 

 

 

H2

Air 0~1% 0~99.999%
N2 0~1% 0~99.999%
O2 0~1% 0~99.999%
Ar 0~1% 0~99.999%
CO 0~1% 0~99.999%

 

 

Ar

Air 0~1% 0~99.99%
N2 0~1% 0~99.99%
O2 0~1% 0~99.99%
CO2 0~1% 0~99.99%
He N2 0~1% 0~99.99%
D2 N2 0~1% 0~99.99%
The component and measure range are costumed be users.

 

Main Features

1. Is based on microprocessor and it has characteristics as intelligence, good stability, high reliability.

2. It adopts heat-conduction sensor as the measuring unit and it has high accuracy, long calibration cycle.

3. 128×64 LCD shows H2 concentration, menu, set value and analyzer work state, etc. It has visualized show and handy operation. Window surface is covered by a toughened glass so it has a good protection effect.

4. Auto range, it will automatically switch analog output range to improve accuracy of analog output according to the range where gas concentration is

5. Interference gas compensation function, eliminate the influence of test by interference gas to improve accuracy of test

6. Menu lock, prevent the influence for analyzer from mis operation.

7. It adopts touch key of the latest technology to extend the service life of buttons.

8. RS485/RS232 (optional) 2-way communication function, can communicate directly with computer or other digital communication equipment.

9. Isolated analog signal output, analog signal mode can be set through analyzer as 4-20mA, 0-20mA, 0-1V, 0-5V, 0-10V freely

10. It has simple structure and it is convenience to operate and maintain.

 

 

Technical Specifications

 

Performance Specifications:

 

Sensor Thermal conductivity sensor
Accuracy ±2%
Repeatability ±1%
Stability ±1%/7d
Response time T90<60s (After preheating enough)
Calibration period Once a year (recommend)
Sensor life More than 2 years(normal use)
Instrument life More than 5 years(normal use)

 

Working Parameters :

 

 

Operation mode

 

Online

 

Sample mode

Plug-in measurement(optional) or ventilation

 

Power supply

AC85~264V,50/60Hz

 

Consumption Less than 20VA

Working temperature

 

Operating: 5~+45℃

Storing: -5~+50℃

Working humidity <90%RH
Intake pressure atmospheric conditions±10% (Gas outlet should be atmospheric conditions)
Intake flow 200~400ml/min

 

 

 

 

Input and Output Parameters:

 

Communication RS485(standard) / RS232(optional)
Switch signal

Quantity: 5 group

Relay contact point capacity: 24VDC, 0.2A

 

Analog signal

Quantity: two group

output mode: 4-20mA/ 0-20mA/ 0-1V/ 0-5V/ 0-10V/ 1-5V, can be set freely

load: less than 500Ω

 

External control

Quantity: 1 group Control signal: 9~28VDC

Function: only used to control the pump(optional)

 

Interference compensation

Quantity: two group

mode: DC 4-20mA (default interference gas is CO,

CO2. If there is other interference gas, please explain when ordering.)

 

 

CI-PC56 Microprocessor Hydrogen Gas Analyzer Thermal Conductivity Type 0

 

CI-PC56 Front/Back Panel Size (unit: mm)

 

 

Applications

 

  1. Air Separation;
  2. Chemical Application;
  3. Wood Gasification;
  4. Gas Detection in Production and Manufacture;
  5. Protection Gas Detection;

 

  1. Gas Detection in Blast Furnace;
  2. Gas Detection for Acidic Converter;
  3. Generator Detection in Hydrogen Refrigeration Generator