BeiJing Cape Golden Gas System Company LTD yelling@golden-cape.com
1000ppm~21% O2 Oxygen Analyzer For Concentrator Real Time Analysis CI-6600

1000ppm~21% O2 Oxygen Analyzer For Concentrator Real Time Analysis CI-6600

  • High Light

    Oxygen Analyzer for Concentrator CE ISO

    ,

    Oxygen Analyzer for Concentrator CI-6600

    ,

    oxygen concentrator purity analyzer Real Time Analysis

  • Sample Gas Flow
    150~300ml/mim
  • Accuracy
    ±2% F.S
  • Ambient Temp
    -10℃~+50℃
  • Stability
    <±1%.FS (168h)
  • Ambient Humidity
    <80%RH
  • Signal Output
    4~20mA
  • Measure Range
    10ppm~21%, 100ppm~21%, 1000ppm~21% O2
  • Range
    10.00~96.00% O2·
  • Place of Origin
    BeiJing
  • Brand Name
    cape golden
  • Certification
    CE ISO
  • Model Number
    CI-6600
  • Minimum Order Quantity
    1
  • Delivery Time
    15 day
  • Payment Terms
    L/C, D/A, D/P, T/T, Western Union, MoneyGram

1000ppm~21% O2 Oxygen Analyzer For Concentrator Real Time Analysis CI-6600

Oxygen Analyzer for Concentrator Real Time Analysis CI-6600

 

CI-6600 trace O2 analyzer is with electrochemical principle and capable of O2 purity measurement range 0-10/100/1000ppm, 1%.

Features

  • 240×128 LCD display oxygen concentration and other settings;
  • Isolated 4-20mA signal output, with 0-100mV, 0-1V and 0-10V as options;
  • Easy to replace sensor;
  • Standard RS232 two-way communication port;
  • Two way SPST alarms;
  • Over pressure protection function and over purity range protection function;
  • Automatic data storage in a certain interval time, and browsing data at any time

Technical Specifications

item
value
Name
oxygen analyzer for concentrator
Model
CI-6600 
Warranty
1 year
Type
3D Ion Current
Certification
CE
Customized support
OEM
Place of Origin
China
 
Beijing
Brand Name
Cape Golden
Model Number
CI-6600
Measure Range
10-99.99% O2
Principle
3D Ion Current
Measure Mode
Online
Install
Dial mounted
Application
Non dangerous general applications
Measure Accuracy
≤±1% F.S.
Stability
≤±0.5% F.S.
Response Time
T90<15s under 25℃
Sample Gas Temperature
0-45℃
Sample Gas Flow
400~600ml/min
Sample Gas Pressure
35-210KPa
Power Supply
AC85~264V, consumption lower than 10VA
Signal Output
4-20mA DC isolated, with 0-1V and 0-10V to switch
Alarm Contact Point
2 way SPST alarm
Display Resolution
0.01%
Communication
RS232 standard (RS485 optional)
Analyzer Size
100 (W) * 100 (H) * 110 (D) mm

Applications

Air separation, Gases production, Protection gas for semi-conductors industry, Wave soldering & reflow soldering, Food production, Petro-chemical, and other oxygen purity detection in inert and hydrocarbon gas mixtures.

 

1000ppm~21% O2 Oxygen Analyzer For Concentrator Real Time Analysis CI-6600 01000ppm~21% O2 Oxygen Analyzer For Concentrator Real Time Analysis CI-6600 1