Portable Oxygen / Nitrogen 1000ppm Gas Analyzer GNL-2100

Portable Oxygen / Nitrogen 1000ppm Gas Analyzer GNL-2100

  • High Light

    1000ppm oxygen gas analyzer

    ,

    iso approved oxygen gas analyzer

    ,

    1000ppm o2 analyser

  • Sample Gas Flow
    150~300ml/mim
  • Accuracy
    ±2% F.S
  • Ambient Temp
    -10℃~+50℃
  • Stability
    <±1%.FS (168h)
  • Ambient Humidity
    <80%RH
  • Signal Output
    4~20mA
  • Measure Range
    10ppm~21%, 100ppm~21%, 1000ppm~21% O2
  • Range
    10.00~96.00% O2·
  • Place of Origin
    BeiJing
  • Brand Name
    cape golden
  • Certification
    CE ISO
  • Model Number
    GNL-2100L
  • Minimum Order Quantity
    1
  • Delivery Time
    15 day
  • Payment Terms
    L/C, D/A, D/P, T/T, Western Union, MoneyGram

Portable Oxygen / Nitrogen 1000ppm Gas Analyzer GNL-2100

GNL-2100Portable oxygen/nitrogen analyzer

 

GNL-2100L purity oxygen analyzer is with ion current principle, which is capable of oxygen purity measurement range 10-99.99%.

GNL - 2100L use 3D ion current sensor for measuring unit, through the sensor signal amplifying, filtering, linearization correction after electric processing, through the microprocessor calculated nitrogen oxygen mixed gas concentration of o2, and provides the oxygen concentration. Analyzer with high precision, good stability, long life and other characteristics, suitable for a variety of environments, nitrogen and oxygen mixed gas of oxygen concentration measurement.

Features

  • with microprocessor as the core, 3D ion current sensor for measuring unit, with intelligent, good stability, high precision, calibration cycle is long, etc;
  • Display intuitive, rich: 128 x 64 LCD screen window shows oxygen concentration, menus, data and equipment working status, display intuitive, rich in content;
  • Technology, using the latest touch buttons, easy to operate, buttons with long life;
  • Long standby time: built-in high capacity lithium battery, normal use, standby time is not less than 8 hours;
  • Change analyzer menu lock switch: to prevent wrong operation parameter affect the normal operation;
  • Alarm function: such as oxygen concentration deviates from the value of the set alarm, the analyzer will send out alarm, alarm value can be set up in full scale range.

Technical Specifications

Portable Oxygen / Nitrogen 1000ppm Gas Analyzer GNL-2100 0

 Portable Oxygen / Nitrogen 1000ppm Gas Analyzer GNL-2100 1