CI-PC21 Infrared Gas Analyzer 1000ppm~21% O2 85-264VAC 50/60HZ

CI-PC21 Infrared Gas Analyzer 1000ppm~21% O2 85-264VAC 50/60HZ

  • High Light

    Infrared Gas Analyzer 85VAC

    ,

    Gas Analyzer CI-PC21

    ,

    infrared gas analyser 264VAC

  • Sample Gas Flow
    150~300ml/mim
  • Accuracy
    ±2% F.S
  • Ambient Temp
    -10℃~+50℃
  • Stability
    <±1%.FS (168h)
  • Ambient Humidity
    <80%RH
  • Signal Output
    4~20mA
  • Measure Range
    10ppm~21%, 100ppm~21%, 1000ppm~21% O2
  • Range
    10.00~96.00% O2·
  • Place of Origin
    BeiJing
  • Brand Name
    cape golden
  • Certification
    CE ISO
  • Model Number
    CI-PC21
  • Minimum Order Quantity
    1
  • Delivery Time
    15 day
  • Payment Terms
    L/C, D/A, D/P, T/T, Western Union, MoneyGram

CI-PC21 Infrared Gas Analyzer 1000ppm~21% O2 85-264VAC 50/60HZ

CI-PC21 Infrared Gas Analyzer

 

The selective absorption of infrared by gas molecules is the basis of the design of infrared gas analyzer.S02,NOx,C02,CO,CH4 and other polar molecules have permanent electric torch, so it has vibration, rotation and other structures. According to quantum mechanics, the energy level of splitting can be coupled with the incident characteristic long infrared radiation to produce absorption, and different polar molecules are absorbed by different spectral bands.

 

Product characteristics:

 

Ø Specially designed gas chamber absorber, narrow-band filter has strong anti-interference ability and high detection accuracy;

Ø High stability infrared light source, receiver constant temperature control, instrument stability;

Ø Measurement of gas chamber mirror gold plating, corrosion resistance;

Ø Isolated analog output, free to set 4-20 mA/0-20mA/0-1V/0-5V/0-10V/1-5V analog output mode;

Ø Alarm function: when the gas concentration deviates from the alarm value, the alarm value can be set arbitrarily within the full range;

Ø Use RS485( standard)/ RS232( selection).

 

Technical parameters:

 

l Model: CI-PC21

l Measuring principle: NDIR non-optical infrared analyzer

l Measuring component: any one or two components can be measured NOx,SO2,CO,CO2,CH4,H2S,. O2 Can be added to each component

 

Range based

Required design

Minimum Range Maximum range
NOx 0 to 1000 ppm 0-20%
SO2 ppm 0-500 0-100%
CO 0 to 20 ppm 0 〜100%
CO2 0 to 10 ppm 0 〜100%
ch4 0 to 200 ppm 0-100%
h2s 0 to WOOppm 0-30%

 

 

Accuracy: ± 2%FS

Repeatability: ±1%FS

Zero drift: ±1%FS/7d

 

Range Drift: ±1%FS/7d

Linear error limit: ±1%FS

Response time: T90<=60 s (sample flow 0.5 L/min)

Analog signal :4~20 mA/0〜20mA/0~1 V/0-5V/0-10V/1-5V, can set analog output mode freely

Maximum load: provided according to user requirements, not affected by load within 500Ω maximum load

Ambient temperature :-10~45°C, ambient humidity: less than 80% RH

Supply voltage :85-264 VAC 50/60HZ

Size :19-inch profile chassis Lx Wx H=483 mm x300mmx 177mm

Gas flow measured: 500~1000 ml/min,500 ml/min best

Dust: particles not exceeding I um, not exceeding 200 μg/Nm3

Pressure :10%± atmospheric pressure (air outlet should be atmospheric pressure)

Moisture: no more than 5 P saturated (no condensation)

 

 

Applications:

 

Widely used in petroleum, chemical, smelting, building materials, light industry and other furnace, kiln or flue gas analysis, environmental monitoring, bioengineering, medical and health research and other reliable testing tools.

 

Notice of Order (Please specify when ordering):

1. Connection:

A,φ6 hose connection (standard)

B,1/4"-φ6 stainless steel jacket

C,1/8"-φ3 stainless steel jacket

2. filters: GF2800,AF2000;

3. the measured gas components and measuring range;

4. gas pressure under test: positive, micro or negative pressure;

5. the main components, impurities, sulfides of the gas under test.